Weighing Indicators
CTZ-52 Smart Weighing Indicator
Available in a plastic 94 X 94 mm box with a rabbet for easily installing it in the frame of any board.
- CE
- Modbus
- RS485

Display of 5 digit LED, 7-segment, waterproof membrane with keys, 5 set points with an A 3 relay output, 2 isolated inputs. Calibrated using the keypad. Can be connected with a PLC or PC through RS232 or RS485 Modbus. Can directly power up to 4 load cells. CE Certified.
CTZ-52 is a programmable weighing instrument with amazing operative capabilities, unique accuracy and weighing speed.
Can be used in any industrial weighing application and automated material dosing, since the user can easily adjust the instrument’s operation to the application’s requirements.
It has 4 Operational modes:
a) Check weigher
b) Dosing materials from 2 to 5, with an option to auto zero range and repeat cycle
CTZ-52 has warranty for a lifetime by PROTEM.
SPECIFICATIONS
| Power Requirements: | 5-24 VAC (50/60 Hz) 0.7A Max. / 12-35 VDC 0.7A Max. |
|---|---|
| Enclosure Construction: | Polycarbonate with IP44 protection grade. Rabbet for easily installing it in the frame of any board. |
| Enclosure Size: | 94 mm W x 94 mm H x 115 mm L |
| Operating Conditions: | Operating Temperature: -10 to +40 ºC Operating Humidity: 85% non-condensing (maximum) |
| Display: | 5 Digit LED Display, 7-segment, 14 mm height |
| Transducer Excitation: | 5 V AC ή DC (selectable) |
| Signal Input Range: | 0.5 mV min. to 40 mV max. |
| Number of Load Cells: | Up to 6, 350 ohm each |
| Load Cells Cable Length: | 10 m (without sense) – 100 m (with sense) |
| Division Value: | 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 |
| Sensitivity: | 0.5uV/ Display Division (Class III) |
| Subdivisions: | 100 to 260,000 (Non-Commercial use) |
| Internal Resolution: | 1 part in 16.777.216 |
| Sample Rate: | 50 to 500 Samples per second (Selectable) |
| Auto Zero Range: | 0.5 or 1 through 9 divisions |
| Keypad: | Membrane, 3 Keys |
| Communication: | (1) Bi-directional RS232 or RS485 Modbus |
| Outputs: | 5 X relay outputs max. 3A/220 Vac |
| Inputs: | 2 X Optical Isolated programmable operation inputs (ex. remote START, ZERO, STOP) |
Photos
Open to new challenges
Connect with us
Do you prefer live communication? So do we!